Solo Series CO2 Scrubbers

SOLO SERIES CO2 SCRUBBERS

SCS is proud to announce their latest Solo Series CO2 scrubbers.

Sized for single rooms, this CO2 scrubber has enormous capacity for its size. Use it at harvest time or as an emergency solution for a room with CO2 out of control. Park it in a hallway, outside the room, or simply inside the room, the twin bed design offers effective CO2 scrubbing for even the lowest of oxygen regimes. Get all the advantages of a whole-store CO2 scrubber with virtually no room PVC piping! Our patent pending N2 bed flush is available as an option if needed.

The PLC, screen, and VFD package on the scrubber allow for 115V wiring with a standard wall plug, minimal kW usage, operator interface, alarms, and ethernet connectivity to larger host computer systems for RUN commands.

  •  Four models available
  •  Place inside room or hallway
  •  Models 100 & 150: 115v single phase power with standard plug
  •  Models 160 & 180: 220-460v single/three-phase power
  •  No extensive room piping
  •  ULO compatible
  •  Ethernet connectivity
  •  Twin-bed scrubbing
  •  Patent-pending nitrogen purge optional

SPECS & DIMENSIONS

Model

Capacity

Width

Depth

Height

Weight

Solo 100

49kg CO2 @ 3.0%

54″

26″

71″

800 pounds

Solo 150

94kg CO2 @ 3.0%

54″

29″

71″

1150 pounds

Solo 160

138kg CO2 @ 3.0%

53″

46″

77″

1525 pounds

Solo 180

171kg CO2 @ 3.0%

82″

35″

78″

1800 pounds

 

Advantages of Using SCS Scrubbers

Built in the USA at SCS facilities

 Top-grade carbon specially formulated for CO2 removal

 8″ touch screen with PLC control

  • Room pressure monitoring and logging
  • Room pressure testing feature
  • MODBUS with SCS controls
  • automatically logs run-time to prove capacity
  • Alarm screen allows shut-down for over pressure and blower failure

 PLC-input driven on-board CO2 analyzer

  • Controls switching of the cycles
  • As the CO2 decreases, the scrub cycle time changes

 Simple, clean, energy-efficient design

  • Typically half the kilowatt draw of competitors units
  • Analyzer-dependent, variable scrub cycle times save energy & increase lifespan of carbon beds
  • Highly-organized design for efficiency as well as aesthetic appeal
  • White powder-coated panels conceal moving parts, keeping everything clean
  • Engineered for easy service

 No auxiliary air compressor required

 No lung to place or maintain

 Direct drive, USA-made blowers eliminate belt headaches

 Variable frequency drives (VFDS)

  • Ensure proper airflow to each room
  • Maximize efficiency on long runs

 Automatic room pressure testing

 Escalated CO2 exposure increases firmness